Planning
Placentia, CA sign permits and sign code: size limits, rules and fees
Placentia, California sign ordinance explained: when a business sign needs a permit, how big a wall sign can be, lighting and Old Town rules, what to submit and where to find the fees, with diagrams, an address check and a sign size calculator.
Updated

Short answer: in Placentia, California (Orange County), almost every exterior business sign needs a sign permit from the Planning Division, including a new face on an existing sign. A lit sign, such as channel letters or a lightbox, also needs a building permit and an electrical permit. In commercial zones, all wall signs on a storefront together can total 1 square foot per linear foot of building frontage, and channel letters can stand no more than 6 inches off the wall. The rules are in Placentia’s sign ordinance, Municipal Code Chapter 23.90.
| Placentia, CA | |
|---|---|
| Permit needed | Every exterior sign, including face changes; only small non-illuminated signs are exempt |
| Who approves | Planning Division (sign plan review), then Building Division (building and electrical permit) |
| Size, commercial zones | 1 sq ft of sign per linear foot of frontage; channel letters 6 in maximum projection |
| Lighting | No flashing, moving or animated signs; Old Town and Packing House District: no change in intensity or color |
| Special areas | Shopping centers: uniform sign program; Old Town and Packing House District: own sign rules |
| Fees | Planning fee schedule · Building permit fee schedule |
| Last checked | November 16, 2026 |
Do you need a sign permit in Placentia?
Yes, for almost any outdoor sign. §23.90.030: a sign permit must be obtained from the Planning Department “prior to the placing, erecting, moving, reconstructing, altering or displaying of any exterior signs, including change of face or copy on existing signs, unless exempted by Section 23.90.060. A building permit and/or electrical permit may also be required.”
That covers new storefront signs, wall signs and channel letters, moving a sign, and swapping the face or lettering of an existing sign.
No permit needed (§23.90.060). The list covers only non-illuminated signs, including:
- one real estate sign up to 6 sq ft and 4 ft high per street frontage,
- one nameplate up to 2 sq ft on a commercial building, mounted parallel to the wall and no more than 4 in from it,
- traffic and municipal signs, legal notices, warning and utility signs,
- on-site directional signs, holiday displays and certain temporary signs.
Every illuminated sign, whether LED channel letters, a lightbox or a neon-style sign, needs a permit.
Who approves signs in Placentia?
| Step | Department | What it checks |
|---|---|---|
| 1. Sign plan review | Planning Division, Development Services Department, 401 E. Chapman Ave, Placentia, CA 92870, (714) 993-8124 | The sign against the sign code: size, placement, lighting, special-area rules |
| 2. Building permit | Building Division | Attachment to the wall, electrical work, and the California Building, Electrical and Energy Codes |
Planning approves first. Under §23.90.040, the Director of Development Services issues a certificate of compliance, and the chief building official then issues the permit. For a lit sign, the electrician handles the electrical side.
Check that the address is in Placentia. The city in a mailing address comes from the ZIP code, not from city limits. An address that says Placentia can be in a neighboring city, or in an unincorporated area that Orange County governs, and then Placentia’s sign code does not apply. Enter the business address to see which city or county has jurisdiction over the property:
How big can a business sign be?
§23.90.180 applies in the C-0, C-1, C-2, C-M and T-C commercial districts:
- Total sign area: “one (1) square foot per lineal foot of the building frontage on which the sign is located” (§23.90.180(3)). The allowance is for every sign on that frontage together.
- No combining: frontages “may not be combined to permit a larger sign on any one (1) building frontage” (§23.90.180(3)(A)).
- Projection: no part of a channel letter or non-illuminated sign more than 6 in from the wall; no part of a cabinet sign more than 12 in (§23.90.180(3)(B)). Wall signs sit parallel to the building face.
- Height: no sign may extend above the roofline or parapet it is attached to (§23.90.100(10)). §23.90.180 sets no letter height limit for wall signs.
- Window signs: inside the window only, covering no more than 25% of the window area (§23.90.180(9)).
- Monument signs: only for businesses that occupy the whole building on a parcel with at least 100 ft of frontage on one street; up to 20 sq ft per 100 ft of frontage and 8 ft above the sidewalk (§23.90.180(5)).
- ABuilding frontage: the width of your storefront along the wall the sign goes on. In Placentia, your sign area allowance is A × 1 sq ft.
- BRoofline or top of the parapet: no part of the sign may go above it.
- CProjection (side view): from the wall to the face of the letters, 6 in maximum for channel letters.
Examples. One line of letters on one frontage, with the sign area measured as a rectangle:
| Storefront frontage | Sign area allowed | Widest sign 18 in tall | 24 in tall | 36 in tall |
|---|---|---|---|---|
| 15 ft | 15 sq ft | 10 ft | 7 ft 6 in | 5 ft |
| 20 ft | 20 sq ft | 13 ft 4 in | 10 ft | 6 ft 8 in |
| 25 ft | 25 sq ft | 16 ft 8 in | 12 ft 6 in | 8 ft 4 in |
| 30 ft | 30 sq ft | 20 ft | 15 ft | 10 ft |
| 40 ft | 40 sq ft | 26 ft 8 in | 20 ft | 13 ft 4 in |
For how tall the letters should be to read from the street, see how tall should sign letters be.
How Placentia measures sign area
§23.90.010 defines sign area as “the entire area within the outside border of the sign.” For letters without a border or background, it is “the entire area within a single continuous perimeter formed by no more than eight (8) straight lines enclosing the extreme limits of writing, representations, emblem, or any figure or similar character.”
- 1One rectangle around both lines: 12 ft × 3 ft 2 in = 38 sq ft.
- 2Outline of eight straight lines, as §23.90.010 allows: 8 ft × 2 ft 4 in + 12 ft × 10 in = 28.7 sq ft, about a quarter less for the same letters.
Show the outline and the calculation on the elevation drawing so the reviewer can check it. More on the common methods: how cities measure sign area.
Sign lighting rules
Citywide (§23.90.100), these are prohibited:
- signs with “flashing moving, or intermittent lighting”,
- rotating or animated signs, or signs with moving parts.
Old Town Placentia (§23.112.070) adds:
- sign lighting “shall not blink, flash, flutter, or change light intensity, brightness, or color”, which rules out color-changing RGB programs,
- external lights such as gooseneck lamps must be shielded so they do not produce glare off the site,
- light sources must be fluorescent or at least as energy efficient; incandescent bulbs are prohibited.
The Packing House District (§23.111.050) prohibits signs that “emit a varying intensity of light or color” and requires sign lighting designed to minimize light and glare on surrounding properties.
California energy code (Title 24 Part 6, 2025), checked by the Building Division for every illuminated sign:
- Power: 12 W per square foot of sign area (§140.8(a)).
- Light source: LED on power supplies of at least 80% efficiency (§140.8(b)).
- Hours: automatic shut-off, such as a time switch set for dusk to closing (§130.3(a)2).
Old Town, Packing House District and shopping center signs
- Shopping centers and other integrated developments: businesses must follow a uniform sign program approved by the Director of Development Services (§23.90.180(4)). Landlord sign criteria usually apply as well, so get them before the sign is designed. The Planning fee schedule has separate lines for an integrated center and for a master sign program.
- Old Town Placentia (Chapter 23.112, sign regulations §23.112.070) and the Transit Oriented Development Packing House District (Chapter 23.111, sign regulations §23.111.050) have their own sign rules. Sign types and sizes not expressly allowed there are prohibited. Prohibited examples include:
- exposed cabinets or raceways behind channel letters,
- internally illuminated cabinet (can) signs,
- animated signs, electronic message displays and signs that vary in light intensity or color,
- in Old Town, pole signs and freestanding signs over 6 ft high.
In these two districts, plan for letters mounted directly to the wall rather than on an exposed raceway, such as halo-lit letters. See raceway vs direct mount.
What to submit for a sign permit
Planning, from the Submittal Requirements: Signs handout:
- Fee, per the current fee schedule. Checks payable to “City of Placentia”.
- Planning Application Worksheet, completed. The property owner signs it; the form asks for a copy of the owner’s driver’s license or a notarized signature.
- Letter of authorization signed by the property owner or landlord, granting permission to install the sign.
- Two sets of plans, to engineering or architectural scale and fully dimensioned:
- Site plan: title block with project name, location and the applicant’s name, address and phone; north arrow and scale; vicinity map; legal property lines and lot dimensions per the current Orange County Assessor’s parcel map; building footprints; setbacks for freestanding signs; signs to be removed or replaced; adjacent rights-of-way; location of the tenant space.
- Elevations: height and width of the building face, the sign’s location on it and the store frontage; a color drawing of the sign to scale with dimensions, lettering and logos, materials, colors and method of illumination; the sign area calculation.
- Structural details: attachment details for wall signs, or footing details for freestanding signs.
- Electrical connection details, if any.
- Plans bound and folded to about 11 x 17 in, in this order: site plan, floor plan(s), elevations.
Building, after Planning approval. Plan check reviews the drawings against the 2025 California Building, Electrical and Energy Codes. The plans should include:
- A cover sheet stating that the project complies with the 2025 California Building Code, Electrical Code and Energy Code, with a sheet index.
- A signature on every sheet by the designer or licensed contractor who prepared the plans (California Business and Professions Code §5536.1).
- An attachment detail with the fastener type and size and the minimum embedment into the wall framing. See mounting letters on brick, stucco and drywall.
- Electrical details. See sign electrical requirements.
- A Title 24 sheet and the NRCC-LTS-E certificate of compliance for sign lighting, generated online through Energy Code Ace (the 2025 version has no paper form).
A resubmittal after plan check corrections includes revised plans, a response letter stating how and where each correction was made, and the final signed drawings.
Our permit drawing package turns your approved sign drawing into these drawings. You or your installer file them with the city.
Sign permit fees and processing time
- Planning fee schedule: sign plan review, integrated center, master sign program and sign face change.
- Building permit fee schedule: sign and sign electrical permits, and plan check.
- Development fees: the city’s fee page.
- Processing time: ask the Planning Division at (714) 993-8124.
Sources and disclaimer
Last checked November 16, 2026:
- Placentia Municipal Code, Chapter 23.90, Signs: §23.90.010, §23.90.030, §23.90.040, §23.90.060, §23.90.100, §23.90.180
- Chapter 23.112, Old Town Placentia, §23.112.070, and Chapter 23.111, Packing House District, §23.111.050
- City of Placentia: Submittal Requirements: Signs, Planning Applications, Building and Safety, online permit portal
- California Title 24 Part 6, 2025 Energy Code, §130.3 and §140.8
This page summarizes public city and state documents for general information. It is not legal advice and not an official city document. Codes, fees and forms change, and the City of Placentia decides what a permit requires. Confirm with the Planning Division before you design or order a sign.
For other cities, see sign permits: what cities ask for.
Placentia, CA sign size calculator
Sign area allowed on this frontage—
Widest sign at that height —
1 sq ft per linear foot of frontage (§23.90.180(3), commercial districts). The allowance covers every sign on that frontage together.
Which city’s sign rules apply to your address?
Uses U.S. Census Bureau city boundaries. Boundaries can change, and the planning department has the final word. The address is not saved.